A vivid Red marker on one conductor of this two conductor parallel construction affords the user a positive circuit identification in all series-parallel blasting patterns (Fig 1.). Wires are individually insulated with tough water and oil resistant yellow plastic insulations. One wire can easily be separated from the other, without special tools, at any point along its length with cutting and splicing both leads (Fig. 2). Field personnel can make easier, quicker connections to the blasting wires. Costing only slightly more than a single connecting wire this easy-strip wire construction is specifically designed and packaged to fulfill the exacting blasting techniques.

Various Colors Are Also Available
Combined with our Standard Yellow and Black colored vinyl Insulation we now offer Pink and Red Insulation for these often difficult series-parallel blasting patterns. A two-color connecting wire system can eliminate costly time consuming check out of wire terminations in large multi-shots. There is no price increase for these colored insulations.


Copper Conductors

Key to Part Number Designation: First two letters indicate Fireworks Wire. Two digits indicate conductor wire gauge. Last letter indicates type of wire construction.

Part Number

Wire Size

Standard Spool Size

Standard Packaging

D.C. Resistance Per 1000 FT. At 25 degrees C

Normal Diameter

FW18D

18

500 & 1,000 FT.

500 FT. = 9 Spools
1,000 FT. = 8 Spools

6.6 ohms each

.1475

FW20D

20

500 & 1,000 FT.

500 FT. = 9 Spools
1,000 FT. = 8 Spools

10.3 ohms each

.1295

FW22D

22

500 & 1,000 FT.

500 FT. = 9 Spools
1,000 FT. = 8 Spools

16.5 ohms each

.1161

FW24D

24

500 & 1,000 FT.

500 FT. = 9 Spools
1,000 FT. = 8 Spools

25.6 ohms each

.1031

FW26D

26

500 & 1,000 FT.

500 FT. = 9 Spools
1,000 FT. = 8 Spools

40.81 ohms each

.072


The Industry standard, Yellow or Black Vinyl-Plastic Insulation is low resistance and has a high breaking strength.

The rapidly growing technical aspects of engineered blasting techniques used by the Pyrotechnic Industry today, demands far greater reliability from the accessories used to detonate the shot. our field proven Vinyl-Plastic insulating compounds meet and surpass the needs for tough, rugged wire insulation. Both oil and water resistant, they are able to take abuse and punishment of rough terrain. These products are compatible with AN/PO type explosions. These wires are designed, engineered, produced, packaged and shipped to fill the needs of all electric blasting systems.

There is no doubt that copper conductors have proven to be the best means of carrying current from a source of electric energy to the end use. Copper is not only a good conductor of electricity but it also has good tensile and flexing strength. Copper connecting wire is almost always of the soft drawn type with no plating or overlay over the metal.

Part Number

Wire Size

Standard Spool Size

Standard Packaging

D.C. Resistance Per 1000 FT. At 25 degrees C

Normal Diameter

FW18S

18

500 & 1,000 FT.

500 FT. = 32 Spools
1,000 FT. = 9 Spools

6.6 ohms each

.070

FW20S

20

500 & 1,000 FT.

500 FT. = 32 Spools
1,000 FT. = 9 Spools

10.3 ohms each

.062

FW22S

22

500 & 1,000 FT.

500 FT. = 32 Spools
1,000 FT. = 9 Spools

16.5 ohms each

.055


"Piggy Back" Connecting Wires
Two individuals solid copper conductors, each distinctly color-coded(1 Red - 1 Yellow) and separated, can be wound together on one spool.

This system allows the shooter to have two colors available without untwisting or pulling the insulated wires apart.

Part Number

Wire Size

Standard Spool Size

Standard Packaging

D.C. Resistance Per 1000 FT. At 25 degrees C

Normal Diameter

FW18PB

2-#.18's

500 & 1,000 FT.

500 FT. = 9 Spools
1,000 FT. = 8 Spools

6.6 ohms each

.1475

FW20PB

2-#.20's

500 & 1,000 FT.

500 FT. = 9 Spools
1,000 FT. = 8 Spools

10.3 ohms each

.1295

FW22PB

2-#.22's

500 & 1,000 FT.

500 FT. = 9 Spools
1,000 FT. = 8 Spools

16.5 ohms each

.1161


 

Metric Unit Spools - and large bulk plywood reels -5,000 to 20,000 feet can be Quoted Upon Request.

              

500' spools. 

1000' spools.

Measurements: 5" flange x 4" wide. Measurements: 6 1/2" flange x 4 1/8" wide.

Call 1-800-346-4378 for current prices.

 

Non-Warranty

The information contained in this catalog is believed to be reliable, but because we are not able to anticipate the many conditions under which the information may be used, Seminole Wire & Cable Co., Inc., makes no warranty concerning the applicability of this information or the suitability of our products in any given situation, nor are any statements in this catalog to be constructed as recommending the infringement of any particular patent.

RED-LINE DUPLEX is a registered trademark in United States Patent and Trademark Office, No. 1,549,071. The DESIGN OF AN INDIAN HEAD is a registered trademark in U.S.P.T.O., No. 1,549,070. The DESIGN OF A REDLINE EXTENDING LONGITUDINALLY ALONG THE GOODS, namely along the length of the Red-Line insulated electric wire for detonating explosives is  a  registered  trademark  in U.S.P.T.O.,  No.  1,516,229.